EV100 Series VFD


EV100 Series VFD 

  EV100 Series VFD


 

  

   Rated Voltage/Frequency: 1PH / 3PH AC 220V, 50 / 60Hz; 3PH AC 380V, 50/60Hz
   Voltage Range: 1PH / 3PH AC170V~240V; 3PH AC 330V~440V
   Voltage: 0~220V AC; 3PH, 0~380V
   Frequency: 0.1~400.0Hz

 

Next:No Next

Kinco EV100 series Genernal VFD High Performance Genernal VFD with Strong Function
Item Description
Input  
Rated Voltage/Frequency 3PH 380V 50 / 60Hz;1PH / 3PH 220V 50 / 60Hz
Voltage Range 380V:330~440V;220V:170V~240V
Output  
Voltage  380V:0~380V;220V:0~220V
Frequency 0.10~400.00Hz
Control Method Vector Control, V/F Control
Display 5 LED display, indicator display. DIsplay the setting frequency, output frequency, output currenct,DC bus voltage, operation state, error and so on.
Control Characteristics  
Output Frequency Range 0.1~400.0Hz
Frequency Resoulution Digital setting: 0.01Hz.   Analog setting: Max. frequency × 0.1%
Output Frequency Accuracy 0.01Hz
V/F Control Can be set as any V/F curve to satisfy various load
Torque Control Torque boosts automatically according to the load; Torque boosts manually: 0.0~20% torque boost can be set
Multi-funtion Input 8 muti-function inputs can be defined as multi-speed(15 different speed at most), switch among 4 accelerations and decelerations, UP/DOWN function, abrupt stop function and so on.
Multi-Funtion Output  3 muti-function outputs can be defined as indicator of operation, zero-speed , external exception, program operation and alarm output .
Accelerations/Decelerations Time Setting 0~6000s can be set as accelerations/decelerations time.
Other Functions  
PID Control Internal PID control
RS485 Standard Modbus RS485 communication
Frequency Setting The frequency can be set via analog 0~10V, 0~20mA, operation key board,
RS485 communication UP/DOWN setting and so on
Multi-Speed 8 inputs terminal can be difined as 15 different speeds.
Regulate Voltage
Automatically
This function can be selected according to actual use.
Counter Two counters are set internally
Copy Parameters from Key Board Use the DP-LED05 / DP-LED06 key board to copy parameters
Protection Functions  
Overload Protection Constant torque: 150%, 1 minute; draught fan;120%, 1 minute 
Overvoltage Protection Over voltage protection level can be set
Undervoltage Protection Under voltage protection level can be set
Other Protections Overheat protection, short-circuit protection,
over current protection, parameter lock and so on.
Enviroment   
Temperature minus 10 ℃ to 40 ℃(Non-freezing)
Humidity  Below 95%(Non-condensing)
Altitude Under1000m
Vibration Below 0.5G
Structure  
Cooling Method Cooling with fan
Protection Class IP20
Installation Method Power under 90KW is wall-mounted; Power from 110~200KW can be wall -mounted
or floor mounting(the feets of floor mounting is 120mm high). Power above 220KW is cabinet mounting